Report for Long Beach Bar (New York) - 1873
| General |
| District: | 3rd |
| Inspector: | Engineer, 3rd LH Dist |
| Location: | Entrance from Gardiner Bay to Orient & Greenport Harbor & to Peconic Bay, Long Island, NY |
| Date of Report: | 12/03/1873 |
| Latitude: | 41° 06' 36" |
| Longitude: | 72° 18' 17" |
| Premises |
| Site: | |
| Date of Reservation: | |
| Date of Deed: | |
| Date of Permission: | |
| Date of Lease: | |
| Area of the Entire Site: | 1849 sq. yds about |
| Area Inclosed: | |
| Character of Soil: | |
| Distance of tower from Nearest High-Water Mark: | |
| Inclosures to Premises / Type of Fence: | |
| Wharf or Landing on Premises: | |
| Road to Land or Wharf Chararacter of and Distance: | |
| Means to Reach Light Station: | By boat |
| Distance to Nearest Road: | About 10 miles from Orient |
| Distance to Post Office: | Orient |
| Distance to Village: | Orient |
| Facilities for Public Conveyance: | None |
| Facilities for Private Conveyance: | Boat |
| Means Used for Support of Lantern: | Tower |
| Number of Separate Lights: | 1 |
| First Built or Established: | 1871 |
| Last Rebuilt, Repaired, or Renovated: | |
| Condition at This Date: | |
| Shape of Tower in Plan: | Octagonal |
| Form of Tower: | |
| Height from Base to Ventilator Ball: | 34' 6" |
| Height of Focal Plane Above Mean High Water: | 56' 4" - mean low water |
| Background of Lighthouse as Seen from Sea: | As seen from Gardiner's Bay - Greenport & vicinity. |
| Color of Tower: | White |
| Color of Tower/ How Produced: | Painted |
| Tower Connection: | Tower surmounts Keeper's dwelling & forms a part. |
| Object of Navigation: | For harbor & channel - local purposes |
| Building Materials: | Principally of wood |
| General Description: | |
| Wall Thickness at Base: | 6Z" |
| Wall Thickness at Parapet: | 3.5" |
| Diameter at Base: | 8' 2" where connected w/ dwelling |
| Diameter at Parapet: | 6' 10 3/4" |
| Kind of Stairway and Steps: | Wooden |
| Number of Landings: | 2 |
| Size of Glass: | 12 x 8" |
| Number of Windows and Size of Sash: | 2 - 3' 5" x 1' 7" |
| Number of Doors: | |
| Kind of Foundation and Depth Below Surface: | Screwpiles driven into soil to depth of 10' |
| Character of Soil Surrounding the Lighthouse: | |
| Soil Susceptibility: | |
| Miscellaneous Remarks: | Apprehensions of insufficiency of rip rap for security of structure are not well founded. 3 enclosed sides are well protected, 4th side towards land is w/o rip rap but drift ice from that direction is not to be apprehended. |
| Lantern and Fixtures |
| Order of Lantern: | 4th |
| Shape of Lantern: | |
| Diameter to Glass: | 6' 10 3/4", exterior |
| Diameter in the Clear: | |
| Number of Sides: | 8 |
| Type of Bars: | |
| Thickness of Bars: | |
| Height Glazed: | 3' |
| Number of Plates in Height: | One |
| Number of Plates Each Side: | One |
| Thickness of Plates: | 1/4" |
| Size of Plates: | 3' high x 2' 8" |
| Number of Storm Panes: | |
| Unglazed Side of Lantern: | |
| What Bearings: | |
| Construction Material Lantern: | Iron & wood |
| Construction Material Roof / Cowl: | Cast iron |
| Ventilator / Cowl: | Cast iron |
| Lightning Spindle: | None |
| Description of Lightning Rod: | |
| Balustrade: | Octagonal in shape & 3' wide with iron railing 3' 5" high. |
| Lantern Doors: | A pair of folding doors hung with 8" brass strap hinges - & 2 - 6" brass bolts. |
| Floor of Lantern: | 2 courses of yellow pine flooring plank covered with sheet copper secured & soldered to render water tight |
| Watchroom Doors: | Hatchway for stairs made of white pine flooring & fitted with galvanized wrought iron hinges & ring. |
| Parapet Diameter: |
| Ventilators |
| Location / Number: | Ventilators 3 in number made of sheet copper & brass placed in lower part of lantern. |
| Ladders / Cleaning Arrangement: | None needed |
| Curtain Hooks / Hanger: | Screwed into astragals of lantern. |
| Watchroom |
| How is Watchroom Fitted: | No fittings |
| How is Relief Called: | None required. |
| Where is Call System Led: |
| Illuminating Apparatus |
| Kind of Apparatus: | |
| Intensity in Candles: | |
| Name of Maker: | |
| Year Made: | |
| Marks and Number: | |
| Order of Apparatus: | 5th |
| Inside Diameter: | |
| Light Characteristic: | Fixed red |
| Time of Revolution: | |
| Flash Interval: | |
| Duration of Flash: | |
| Arc of Each Fixed Part: | Fixed - arc 360 degrees Range of visibility - entire horizon. |
| Number of Panels: | 4 |
| Number of Flash Panels: | |
| Arc of Each: | |
| Number of Elements in Central Drum: | |
| Number of Prisms Above Center Drum: | 5 |
| Number of Prisms Below Center Drum: | 3 |
| Does Apparatus Revolve?: | False |
| Is There a Revolving Belt?: | False |
| Revolving Panels: | |
| How Flash is Produced: | |
| Number of Vertical Elements Panel: | |
| Fixed Lens Covered: | |
| Pedestal: | Cast iron |
| Service Table: | Wrought iron frame covered with sheet iron |
| Draft Tube Description: | Made of sheet copper - 7" dia. (internal) fitted to center ring of lantern roof & secured with screws not connected with damper tube. |
| Revolving Machinery: | |
| Standby and Description: | |
| Chariot Float or Balls: | |
| Chariot Description: | |
| Length of Drop Tube: | |
| Clock Weight: | |
| Length of Winding Time: | |
| Drive During Rewind: | |
| Machinery Protection: | |
| Regulated: | |
| Lens Protection: | |
| How Color is Produced: | By red chimney |
| Red Sectors Description: | |
| Where Color Attached: | |
| Form of Colored Glass: | |
| Lamp Description: | 5th order Funck, 1 wick |
| Type of Illuminant: | |
| Number of Spare Lamps: | 1 spare lamp complete |
| Number of Spare Burners: | 1 |
| Candle Power: |
| Closets and Store Rooms |
| Tower Closet Use: | None |
| Oil House Description: | Placed in 2nd story of dwelling & fitted out w/ wooden stand for oil butts, a box for spare glass (plate & window) a workbench & closet shelves |
| Oil House Inside Dimension: | |
| Oil House Construction Material: | |
| Oil House Capacity: | 3 50-gallon oil butts. |
| Other (Describe): | Coal closet, pantry on 1st floor fitted w/ shelves etc. Also, closets in each of 2nd story rooms. |
| Suitability: | Dry & suited. |
| Fog Signal General |
| Fog Signal Kind: | A cast steel bell struck by machinery Steven's striking apparatus. |
| Time to Start: | |
| How Long Will Pressure Last: | |
| Manufacturer: | |
| Year of Manufacture: | |
| Characteristic: | Struck every 15 sec. |
| Duplication: | |
| Timing Device: | |
| If whistle, siren, or trumpet, Pressure at Which Blown: | |
| Height Above Water: | |
| Compass Direction: | |
| Location: | Placed on S front of lighthouse. |
| Distance and Direction: | |
| Water Supply: | |
| Reached from Lighthouse: | |
| Description of Fog Signal Building: | |
| Pressure And Recording Gauge: |
| Dwelling |
| Location: | Immediately under tower |
| Coloring: | |
| Construction Materials: | Wood |
| Number of Rooms: | 6 - kitchen & sitting room 1st floor; 3 bedrooms & oil room, 2nd floor. |
| Number of Dwellings: | |
| Heating Plant: | |
| Number of Keepers: | |
| Furnished Quarters: | |
| NOT Furnished Quarters: | |
| Outhouses: | |
| Outhouse Coloring: | |
| Paths and Walks: | |
| Area Inclosed: | |
| Area of Garden: | |
| Area Timber or Shrubbery: | |
| Cultivation Area Available: | |
| Area Cultivated: | |
| Character of Surroundings: | |
| Stove, Maker: | |
| Stove, Size: | |
| Sink, Maker: | |
| Sink, Size: | |
| Pump, Maker: | |
| Pump, Size: | |
| Lamps: |
| Water |
| How Procured: | Rain water from roof of dwelling |
| Quality: | |
| Quantity: | |
| Injury Possible: | Not liable |
| Purity Precaution: | |
| Tank Capacity: | 2 tanks of 219 gallons each, placed in kitchen & one of 359 gal adjoining hall, making total supply of 797 gallons. |
| Tank Material: | Of plate iron. |
| Distilling Apparatus: | False |
| Distilling Manufacturer: | |
| Well Description: | |
| Well Diameter: | |
| Well Lining: | |
| Pump or Bucket: | |
| What Power Used: | |
| Distance from Dwelling: |
| Healthfulness |
| General Opinion: | Good |
| Diseases: | Unknown |
| Prevalency: | |
| Local Causes: | None |
| Recommended Improvements: |
| Miscellaneous |
| Access to Lighthouse: | |
| Distance and Direction: | |
| Miscellaneous Remarks: | Machinery of fog bell has been irregular in its movement in consequence of use of refuse oil. Use of clock oil has recently remedied the irregularity. |
| Tools And Accessories |
| Lantern Curtains: | |
| Lens Covers: | |
| Damper Tube and Key: | 1 |
| Spare Damper and Key: | |
| Carillon for Overflow Pump: | |
| Time Marker: | |
| Gauge: | |
| Spare Lamp Ready for Use: | 1 |
| Rod Lamp Ready for Use: | 1 |
| Curtain Hanger: | |
| Heater: | None |
| Spare Lamp Cover: | None |
| Lamp Stand: | None |
| Mechanical Lamp Cords: | |
| Revolving Machinery Cords: | |
| Revolving Machinery Weights: | |
| Clutch: | |
| Spare Fly Or Governor: | |
| Gauge for Oil Cistern: | |
| Feather Brushes: | |
| Linen Towels: | |
| Sponges: | |
| Chamois Skins: | |
| Scissors: | |
| Chimney Filters: | |
| Coupling Pliers: | |
| Service Box and Implements: | |
| Cleaning Materials: | |
| Keepers Aprons: | |
| Wicks: |