Report for Hatteras Inlet Light-Station (North Carolina) - 1909

General
District: 5th
Inspector: John Murdoch, Assistant Light-House Engineer
Location: Hatteras Inlet, NC, on the NW'ly end of Oliver Reef, S'ly side of Pamlico Sound, about 4 miles inside of the seaward entrance to Hateras Inlet, and on the E'ly side of the channel from the inlet into the sound.
Date of Report: 11/21/1909
Latitude: 35° 15' 48"
Longitude: 75° 45' 38"
Premises
Site: Submarine
Date of Reservation:
Date of Deed:
Date of Permission:
Date of Lease:
Area of the Entire Site:
Area Inclosed:
Character of Soil:
Distance of tower from Nearest High-Water Mark:
Inclosures to Premises / Type of Fence:
Wharf or Landing on Premises:
Road to Land or Wharf Chararacter of and Distance:
Means to Reach Light Station: By railroad to Elizabeth City, NC. By steamer to Mantio, NC. By mail boat to hatteras, and small boat to station.
Distance to Nearest Road: 50 miles to steamboat landing, Manteo, Roanoke Island, NC.
Distance to Post Office: 10 miles to Buxton
Distance to Village: 4 miles to Hatteras
Facilities for Public Conveyance: None.
Facilities for Private Conveyance: By small boat, 4 miles.
Means Used for Support of Lantern: Dwelling
Number of Separate Lights: 1
First Built or Established: 1874
Last Rebuilt, Repaired, or Renovated: March, 1908
Condition at This Date: Good
Shape of Tower in Plan: Square structure.
Form of Tower: No tower.
Height from Base to Ventilator Ball:
Height of Focal Plane Above Mean High Water: 38 feet
Background of Lighthouse as Seen from Sea: Sky
Color of Tower: White; substructure brown.
Color of Tower/ How Produced: By paint.
Tower Connection:
Object of Navigation: Local purposes.
Building Materials:
General Description:
Wall Thickness at Base:
Wall Thickness at Parapet:
Diameter at Base:
Diameter at Parapet:
Kind of Stairway and Steps: Wood
Number of Landings: 2
Size of Glass: 8" x 12"
Number of Windows and Size of Sash: 10; 26.5" x 28.5" x 1.5"
Number of Doors: 12
Kind of Foundation and Depth Below Surface: Iron piles with screws, supplemented by iron sleeves with disks around the piles; 7 feet.
Character of Soil Surrounding the Lighthouse:
Soil Susceptibility:
Miscellaneous Remarks:
Lantern and Fixtures
Order of Lantern: 4th
Shape of Lantern: Polygonal
Diameter to Glass: 7 feet
Diameter in the Clear:
Number of Sides: 9
Type of Bars: Vertical
Thickness of Bars:
Height Glazed: 36"
Number of Plates in Height: 1
Number of Plates Each Side: 1
Thickness of Plates: 3/8"
Size of Plates: 36" x 28.5"
Number of Storm Panes: None
Unglazed Side of Lantern:
What Bearings:
Construction Material Lantern: Copper, iron & wood.
Construction Material Roof / Cowl: Copper
Ventilator / Cowl: Copper
Lightning Spindle: Brass
Description of Lightning Rod: Copper, fastened to sill o lantern, led over roof to side of house to water.
Balustrade: Wood
Lantern Doors: Fitted with hinges fastened to frame of lantern.
Floor of Lantern: Wood
Watchroom Doors: None
Parapet Diameter:
Ventilators
Location / Number: Lower portion of lantern.
Ladders / Cleaning Arrangement: None
Curtain Hooks / Hanger: Screwed into frame of lantern.


Watchroom
How is Watchroom Fitted: None
How is Relief Called:
Where is Call System Led:
Illuminating Apparatus
Kind of Apparatus:
Intensity in Candles:
Name of Maker: L. Sautter Co., Paris
Year Made: Unknown.
Marks and Number: None
Order of Apparatus: 4th
Inside Diameter: 19.5"
Light Characteristic: Fixed red.
Time of Revolution:
Flash Interval:
Duration of Flash:
Arc of Each Fixed Part:
Number of Panels: 4
Number of Flash Panels: None
Arc of Each:
Number of Elements in Central Drum: 5
Number of Prisms Above Center Drum: 5
Number of Prisms Below Center Drum: 3
Does Apparatus Revolve?: False
Is There a Revolving Belt?: False
Revolving Panels:
How Flash is Produced:
Number of Vertical Elements Panel:
Fixed Lens Covered:
Pedestal: Iron
Service Table: None. Trimming table of wood covered with zinc.
Draft Tube Description: None.
Revolving Machinery:
Standby and Description:
Chariot Float or Balls:
Chariot Description:
Length of Drop Tube:
Clock Weight:
Length of Winding Time:
Drive During Rewind:
Machinery Protection:
Regulated:
Lens Protection:
How Color is Produced: By red chimneys
Red Sectors Description: None.
Where Color Attached:
Form of Colored Glass:
Lamp Description: Improved 1 wick
Type of Illuminant:
Number of Spare Lamps: 2
Number of Spare Burners: None.
Candle Power:
Closets and Store Rooms
Tower Closet Use:
Oil House Description: Oil stored in closet on 2nd floor of dwelling on oil stands covered with zinc.
Oil House Inside Dimension:
Oil House Construction Material:
Oil House Capacity:
Other (Describe): On 1st floor, fitted with shelves for general purposes.
Suitability: Dry & suitable.
Fog Signal General
Fog Signal Kind: Stevens bell machine.
Time to Start: 2 minutes.
How Long Will Pressure Last:
Manufacturer: Geo. M. Stevens Co., Boston, Mass
Year of Manufacture: Unknown.
Characteristic: A single blow every 8 seconds.
Duplication: None
Timing Device:
If whistle, siren, or trumpet, Pressure at Which Blown:
Height Above Water:
Compass Direction:
Location:
Distance and Direction:
Water Supply:
Reached from Lighthouse:
Description of Fog Signal Building:
Pressure And Recording Gauge:
Bell Signal
Weight: 1000
Metal: Bell metal
Diameter: 30"
Height: 22"
Time: 3/4 hour.
Manufacturer:
Weights for Operation:
Dwelling
Location: No tower.
Coloring: White
Construction Materials: Wood
Number of Rooms: 5
Number of Dwellings:
Heating Plant:
Number of Keepers: 1 keeper & 1 assistant.
Furnished Quarters:
NOT Furnished Quarters:
Outhouses:
Outhouse Coloring:
Paths and Walks:
Area Inclosed:
Area of Garden:
Area Timber or Shrubbery:
Cultivation Area Available:
Area Cultivated:
Character of Surroundings: Sandy
Stove, Maker:
Stove, Size:
Sink, Maker:
Sink, Size:
Pump, Maker:
Pump, Size:
Lamps:
Water
How Procured: From roof.
Quality: Good
Quantity: Ample
Injury Possible: Not liable.
Purity Precaution: Tanks cleaned twice each year.
Tank Capacity: 3 tanks, 200 gallons each, on 1st floor.
Tank Material: Iron
Distilling Apparatus: False
Distilling Manufacturer:
Well Description:
Well Diameter:
Well Lining:
Pump or Bucket:
What Power Used:
Distance from Dwelling:
Healthfulness
General Opinion: Generally healthy.
Diseases: Malarial.
Prevalency: Spring & fall.
Local Causes: No.
Recommended Improvements: