Report for Rochester Harbor East Pier Light (New York) - 1909
| General |
| District: | 10th |
| Inspector: | Chas. Bartlett, Chief Clerk and Norris Works, Supt |
| Location: | On East Pier, 40' from outer end, entrance to Charlotte Harbor, mouth of Genesee River, shore of Lake Ontario |
| Date of Report: | 01/03/1909 |
| Latitude: | 43° 15' 46" |
| Longitude: | 77° 36' 01" |
| Premises |
| Site: | On US Pier |
| Date of Reservation: | |
| Date of Deed: | |
| Date of Permission: | |
| Date of Lease: | |
| Area of the Entire Site: | |
| Area Inclosed: | |
| Character of Soil: | |
| Distance of tower from Nearest High-Water Mark: | On pier |
| Inclosures to Premises / Type of Fence: | |
| Wharf or Landing on Premises: | Tower stands on US East Pier |
| Road to Land or Wharf Chararacter of and Distance: | |
| Means to Reach Light Station: | By walking out E Pier from shore, 2200' (when repairs to pier, now in progress, are completed). By boat from W Pier light 600' |
| Distance to Nearest Road: | |
| Distance to Post Office: | |
| Distance to Village: | |
| Facilities for Public Conveyance: | |
| Facilities for Private Conveyance: | |
| Means Used for Support of Lantern: | Wooden, inclosed tower |
| Number of Separate Lights: | 1 |
| First Built or Established: | 1902 |
| Last Rebuilt, Repaired, or Renovated: | Cornice repaired, Jan. 1908 |
| Condition at This Date: | Good |
| Shape of Tower in Plan: | Square |
| Form of Tower: | Pyramidal |
| Height from Base to Ventilator Ball: | 34' 10" |
| Height of Focal Plane Above Mean High Water: | 34' |
| Background of Lighthouse as Seen from Sea: | Bldgs among green trees |
| Color of Tower: | White, black lantern |
| Color of Tower/ How Produced: | Lead & oil paint |
| Tower Connection: | Detached |
| Object of Navigation: | Marks extremity of E Pier, entrance to Charlotte Harbor. |
| Building Materials: | Wood |
| General Description: | |
| Wall Thickness at Base: | 10" |
| Wall Thickness at Parapet: | 10", lantern parapet 7.5" |
| Diameter at Base: | 12' |
| Diameter at Parapet: | 7' 8" - parapet of lantern 7' 11 3/4" |
| Kind of Stairway and Steps: | Wooden winding to 2nd floor landing - wooden step ladder to lantern. |
| Number of Landings: | 1 intermediate |
| Size of Glass: | 10" x 20" for 2 windows, 4 lights each; 10" x 16" for 1 window 2 lights each. |
| Number of Windows and Size of Sash: | 3 |
| Number of Doors: | 1 outside, with storm door on vestibule. |
| Kind of Foundation and Depth Below Surface: | Interior of crib superstructure beneath beacon filled with a mass of concrete & stone up to top of timber superstructure. Beacon rests on 8 concrete piers 3' 7" high, resting on concrete deck. |
| Character of Soil Surrounding the Lighthouse: | |
| Soil Susceptibility: | |
| Miscellaneous Remarks: |
| Lantern and Fixtures |
| Order of Lantern: | 4th |
| Shape of Lantern: | Polygonal, parapet cylindrical. |
| Diameter to Glass: | 7' 1.5" |
| Diameter in the Clear: | |
| Number of Sides: | 10 |
| Type of Bars: | Vertical |
| Thickness of Bars: | |
| Height Glazed: | 36" |
| Number of Plates in Height: | One |
| Number of Plates Each Side: | One |
| Thickness of Plates: | 5/16" |
| Size of Plates: | 24" x 39" |
| Number of Storm Panes: | None |
| Unglazed Side of Lantern: | None |
| What Bearings: | |
| Construction Material Lantern: | Cast iron lantern on wooden parapet. Lantern was formerly in use on beacon, Cleveland W. Pier |
| Construction Material Roof / Cowl: | Cast iron |
| Ventilator / Cowl: | Cast iron |
| Lightning Spindle: | Steel, platinum point |
| Description of Lightning Rod: | 1/2" copper, wired to spindle, thence down to railing of balcony & down E side of tower, thru concrete pier, into water. |
| Balustrade: | Wood, covered with copper. Iron railing of 2 rails, top & bottom, 1/2" x 2", supported by 12 posts, 1.5" |
| Lantern Doors: | Low wooden door in parapet, opens out. |
| Floor of Lantern: | Wood |
| Watchroom Doors: | Wooden trap |
| Parapet Diameter: | 6' 8 3/4" |
| Ventilators |
| Location / Number: | 5 in parapet wall |
| Ladders / Cleaning Arrangement: | None |
| Curtain Hooks / Hanger: | Hooks screwed into upper part of posts |
| Watchroom |
| How is Watchroom Fitted: | Utensils for filling & cleaning lamps, etc. |
| How is Relief Called: | |
| Where is Call System Led: |
| Illuminating Apparatus |
| Kind of Apparatus: | |
| Intensity in Candles: | |
| Name of Maker: | Not known |
| Year Made: | |
| Marks and Number: | |
| Order of Apparatus: | Lens lantern with 5 day tank |
| Inside Diameter: | 11 13/16" |
| Light Characteristic: | Fixed red. |
| Time of Revolution: | |
| Flash Interval: | |
| Duration of Flash: | |
| Arc of Each Fixed Part: | 360 degrees |
| Number of Panels: | 3 |
| Number of Flash Panels: | |
| Arc of Each: | |
| Number of Elements in Central Drum: | 1 |
| Number of Prisms Above Center Drum: | 3 |
| Number of Prisms Below Center Drum: | 3 |
| Does Apparatus Revolve?: | False |
| Is There a Revolving Belt?: | False |
| Revolving Panels: | |
| How Flash is Produced: | |
| Number of Vertical Elements Panel: | |
| Fixed Lens Covered: | |
| Pedestal: | Wood |
| Service Table: | Wood |
| Draft Tube Description: | None |
| Revolving Machinery: | |
| Standby and Description: | |
| Chariot Float or Balls: | |
| Chariot Description: | |
| Length of Drop Tube: | |
| Clock Weight: | |
| Length of Winding Time: | |
| Drive During Rewind: | |
| Machinery Protection: | |
| Regulated: | |
| Lens Protection: | |
| How Color is Produced: | Ruby Chimney |
| Red Sectors Description: | |
| Where Color Attached: | |
| Form of Colored Glass: | |
| Lamp Description: | 5th order |
| Type of Illuminant: | |
| Number of Spare Lamps: | 2 |
| Number of Spare Burners: | None |
| Candle Power: |
| Vapor Oil Lamp |
| Number of Wicks or Mantels: | 1 round wick |
| Diameter of Outside Wick: | 1 1/4" |
| Diameter of Mantel: | |
| Diameter of Circum Circle: |
| Closets and Store Rooms |
| Tower Closet Use: | Large closet under stairs in 1st story, in which are stored chimneys & supplies. |
| Oil House Description: | Oil kept in iron oil house, located on W Pier. |
| Oil House Inside Dimension: | |
| Oil House Construction Material: | |
| Oil House Capacity: | |
| Other (Describe): | |
| Suitability: |
| Water |
| How Procured: | From lake for scrubbing & cleaning. |
| Quality: | |
| Quantity: | |
| Injury Possible: | |
| Purity Precaution: | |
| Tank Capacity: | |
| Tank Material: | |
| Distilling Apparatus: | False |
| Distilling Manufacturer: | |
| Well Description: | |
| Well Diameter: | |
| Well Lining: | |
| Pump or Bucket: | |
| What Power Used: | |
| Distance from Dwelling: |
| Healthfulness |
| General Opinion: | Healthful |
| Diseases: | |
| Prevalency: | |
| Local Causes: | |
| Recommended Improvements: |
| Miscellaneous |
| Access to Lighthouse: | Beacon stands on harbor piers. Boat kept at W Pier light, opposite. |
| Distance and Direction: | |
| Miscellaneous Remarks: | Beacon was established in 1902 & at same time, the West Pier Range Beacon, an open skeleton tower with work room at base & hoisting lens lantern, built in 1899, was discontinued & removed. |