Report for Bordens Flats (Massachusetts) - 1887

General
District: 3rd
Inspector: Lieut. John Millis, Eng'r 3rd Dist.
Location: Mount Hope Bay, MA
Date of Report: 01/03/1887
Latitude:
Longitude:
Premises
Site:
Date of Reservation:
Date of Deed:
Date of Permission:
Date of Lease:
Area of the Entire Site: Circle 200' dia.
Area Inclosed:
Character of Soil:
Distance of tower from Nearest High-Water Mark: High water line on pier
Inclosures to Premises / Type of Fence:
Wharf or Landing on Premises:
Road to Land or Wharf Chararacter of and Distance:
Means to Reach Light Station: Small boat
Distance to Nearest Road: 1/2 mile to Old Colony steamboat wharf, Fall River, MA
Distance to Post Office: 1 mile to Fall River
Distance to Village: 1/2 mile to Fall River
Facilities for Public Conveyance:
Facilities for Private Conveyance: Small boat from Old Colony steamboat wharf 1/2 mile.
Means Used for Support of Lantern: Tower
Number of Separate Lights: 1
First Built or Established: 1881
Last Rebuilt, Repaired, or Renovated:
Condition at This Date: Good
Shape of Tower in Plan: Circular
Form of Tower:
Height from Base to Ventilator Ball: 37'
Height of Focal Plane Above Mean High Water: 50'
Background of Lighthouse as Seen from Sea: Land
Color of Tower: Red
Color of Tower/ How Produced: Painted
Tower Connection: In tower
Object of Navigation: To keep clear of flats & local navigating
Building Materials: Iron lined with brick
General Description:
Wall Thickness at Base: 18"
Wall Thickness at Parapet: 4"
Diameter at Base: 21'
Diameter at Parapet: 18'
Kind of Stairway and Steps: Iron
Number of Landings: 5
Size of Glass: 10.5" x 21"
Number of Windows and Size of Sash: 5 - 2' x 4' 6"
Number of Doors: 1
Kind of Foundation and Depth Below Surface: Iron shell filled with Portland cement concrete 2' below surface.
Character of Soil Surrounding the Lighthouse:
Soil Susceptibility:
Miscellaneous Remarks: Iron shell 30' dia. sunk in 13' water (l.w) 30' high filled with Portland cement concrete forms pier upon which tower is built.
Lantern and Fixtures
Order of Lantern: 4th
Shape of Lantern:
Diameter to Glass: 7' 7.5"
Diameter in the Clear:
Number of Sides: 10
Type of Bars:
Thickness of Bars:
Height Glazed: 3' 3 3/8"
Number of Plates in Height: One
Number of Plates Each Side: One
Thickness of Plates: 3/8"
Size of Plates: 27 3/8" x 36 3/8"
Number of Storm Panes:
Unglazed Side of Lantern:
What Bearings:
Construction Material Lantern: Iron
Construction Material Roof / Cowl: Iron
Ventilator / Cowl: Zinc lining
Lightning Spindle:
Description of Lightning Rod:
Balustrade: Iron posts, gas pipe rail on iron deck.
Lantern Doors: Iron hung on hinges
Floor of Lantern: Iron
Watchroom Doors: Wooden trap door iron hinges.
Parapet Diameter:
Ventilators
Location / Number: Lower part of lantern
Ladders / Cleaning Arrangement:
Curtain Hooks / Hanger: Screwed in iron frames.


Watchroom
How is Watchroom Fitted: Ladder to lantern & fog bell machinery
How is Relief Called:
Where is Call System Led:
Illuminating Apparatus
Kind of Apparatus:
Intensity in Candles:
Name of Maker:
Year Made:
Marks and Number:
Order of Apparatus: 5th
Inside Diameter:
Light Characteristic: Fixed red
Time of Revolution:
Flash Interval:
Duration of Flash:
Arc of Each Fixed Part: Fixed 270 degrees from NW around by E & S to W.
Number of Panels: 3
Number of Flash Panels:
Arc of Each:
Number of Elements in Central Drum:
Number of Prisms Above Center Drum: 7
Number of Prisms Below Center Drum: 6
Does Apparatus Revolve?: False
Is There a Revolving Belt?: False
Revolving Panels:
How Flash is Produced:
Number of Vertical Elements Panel:
Fixed Lens Covered:
Pedestal: Iron
Service Table: Iron
Draft Tube Description: Red chimney
Revolving Machinery:
Standby and Description:
Chariot Float or Balls:
Chariot Description:
Length of Drop Tube:
Clock Weight:
Length of Winding Time:
Drive During Rewind:
Machinery Protection:
Regulated:
Lens Protection:
How Color is Produced: Red chimney
Red Sectors Description:
Where Color Attached:
Form of Colored Glass:
Lamp Description: Hains lamp
Type of Illuminant:
Number of Spare Lamps: 1
Number of Spare Burners:
Candle Power:
Closets and Store Rooms
Tower Closet Use: Built in brick lining, fitted with drawers & shelves. Used for clothes presses, dishes, etc.
Oil House Description: In basement of pier
Oil House Inside Dimension:
Oil House Construction Material:
Oil House Capacity: 36 5-gal cans.
Other (Describe): Storeroom in basement, 1 closet on 1st, 3rd, 4th & 2 on 2nd floor.
Suitability: Well suited.
Fog Signal General
Fog Signal Kind: Steven's fog bell & apparatus operated by machinery
Time to Start:
How Long Will Pressure Last:
Manufacturer:
Year of Manufacture:
Characteristic: 1 stroke every 15 sec.
Duplication:
Timing Device:
If whistle, siren, or trumpet, Pressure at Which Blown:
Height Above Water:
Compass Direction:
Location: To clear Borden Flats, attached to tower.
Distance and Direction:
Water Supply:
Reached from Lighthouse:
Description of Fog Signal Building:
Pressure And Recording Gauge:
Dwelling
Location: In tower
Coloring:
Construction Materials: Iron & brick
Number of Rooms: 5
Number of Dwellings:
Heating Plant:
Number of Keepers: 1
Furnished Quarters:
NOT Furnished Quarters:
Outhouses: 1
Outhouse Coloring:
Paths and Walks:
Area Inclosed:
Area of Garden:
Area Timber or Shrubbery:
Cultivation Area Available:
Area Cultivated:
Character of Surroundings:
Stove, Maker:
Stove, Size:
Sink, Maker:
Sink, Size:
Pump, Maker:
Pump, Size:
Lamps:
Water
How Procured: Cistern
Quality: Good
Quantity: Generally ample
Injury Possible: No
Purity Precaution: Filters
Tank Capacity: 2500 gals
Tank Material: Brick lined or plastered with cement mortar.
Distilling Apparatus: False
Distilling Manufacturer:
Well Description:
Well Diameter:
Well Lining:
Pump or Bucket: Pump in sink
What Power Used:
Distance from Dwelling:
Healthfulness
General Opinion: Good
Diseases:
Prevalency:
Local Causes:
Recommended Improvements:
Miscellaneous
Access to Lighthouse: Land from small boat - no wharf. Boat davits.
Distance and Direction:
Miscellaneous Remarks: In good condition.