Report for Negro Point (New York) - 1915
| General |
| District: | 3rd |
| Inspector: | Oscar C. Luther |
| Location: | On point S end of Ward's Island. On island is state hospital for insane. Regular trips to & from island are made by steamer connected with hospital |
| Date of Report: | 05/03/1915 |
| Latitude: | 40° 46' 52" |
| Longitude: | 73° 55' 40" |
| Premises |
| Site: | Deed from City of NY |
| Date of Reservation: | |
| Date of Deed: | 02/26/1905 |
| Date of Permission: | |
| Date of Lease: | |
| Area of the Entire Site: | 4,607.41 sq. ft. |
| Area Inclosed: | |
| Character of Soil: | |
| Distance of tower from Nearest High-Water Mark: | 13' |
| Inclosures to Premises / Type of Fence: | No fence |
| Wharf or Landing on Premises: | Neither |
| Road to Land or Wharf Chararacter of and Distance: | |
| Means to Reach Light Station: | Boat. There is mail service maintained by messenger btwn hospital & main land. Address of Keeper, Hospital, Wards Island, NY. |
| Distance to Nearest Road: | |
| Distance to Post Office: | |
| Distance to Village: | |
| Facilities for Public Conveyance: | |
| Facilities for Private Conveyance: | |
| Means Used for Support of Lantern: | Tower |
| Number of Separate Lights: | 1 |
| First Built or Established: | 1913 |
| Last Rebuilt, Repaired, or Renovated: | Never rebuilt |
| Condition at This Date: | |
| Shape of Tower in Plan: | |
| Form of Tower: | |
| Height from Base to Ventilator Ball: | |
| Height of Focal Plane Above Mean High Water: | 34' |
| Background of Lighthouse as Seen from Sea: | Bldgs in NY City |
| Color of Tower: | Red |
| Color of Tower/ How Produced: | Paint |
| Tower Connection: | No keeper's dwelling at this station |
| Object of Navigation: | Channel light, for general navigation. |
| Building Materials: | Iron on concrete foundation |
| General Description: | |
| Wall Thickness at Base: | |
| Wall Thickness at Parapet: | |
| Diameter at Base: | |
| Diameter at Parapet: | |
| Kind of Stairway and Steps: | Iron steps |
| Number of Landings: | |
| Size of Glass: | No windows in tower |
| Number of Windows and Size of Sash: | |
| Number of Doors: | |
| Kind of Foundation and Depth Below Surface: | |
| Character of Soil Surrounding the Lighthouse: | |
| Soil Susceptibility: | |
| Miscellaneous Remarks: |
| Lantern and Fixtures |
| Order of Lantern: | 200 mm buoy lantern |
| Shape of Lantern: | |
| Diameter to Glass: | |
| Diameter in the Clear: | |
| Number of Sides: | |
| Type of Bars: | |
| Thickness of Bars: | |
| Height Glazed: | |
| Number of Plates in Height: | |
| Number of Plates Each Side: | |
| Thickness of Plates: | |
| Size of Plates: | |
| Number of Storm Panes: | |
| Unglazed Side of Lantern: | |
| What Bearings: | |
| Construction Material Lantern: | |
| Construction Material Roof / Cowl: | |
| Ventilator / Cowl: | |
| Lightning Spindle: | |
| Description of Lightning Rod: | |
| Balustrade: | Gallery around lantern. |
| Lantern Doors: | |
| Floor of Lantern: | |
| Watchroom Doors: | |
| Parapet Diameter: |
| Watchroom |
| How is Watchroom Fitted: | No watchroom. There is a small concrete house adjoining tower foundation used as watchroom for fog signal. |
| How is Relief Called: | |
| Where is Call System Led: |
| Illuminating Apparatus |
| Kind of Apparatus: | |
| Intensity in Candles: | 70 |
| Name of Maker: | |
| Year Made: | |
| Marks and Number: | None |
| Order of Apparatus: | |
| Inside Diameter: | |
| Light Characteristic: | |
| Time of Revolution: | |
| Flash Interval: | |
| Duration of Flash: | |
| Arc of Each Fixed Part: | |
| Number of Panels: | |
| Number of Flash Panels: | |
| Arc of Each: | |
| Number of Elements in Central Drum: | |
| Number of Prisms Above Center Drum: | |
| Number of Prisms Below Center Drum: | |
| Does Apparatus Revolve?: | False |
| Is There a Revolving Belt?: | False |
| Revolving Panels: | |
| How Flash is Produced: | |
| Number of Vertical Elements Panel: | |
| Fixed Lens Covered: | |
| Pedestal: | |
| Service Table: | |
| Draft Tube Description: | |
| Revolving Machinery: | |
| Standby and Description: | |
| Chariot Float or Balls: | |
| Chariot Description: | |
| Length of Drop Tube: | |
| Clock Weight: | |
| Length of Winding Time: | |
| Drive During Rewind: | |
| Machinery Protection: | |
| Regulated: | |
| Lens Protection: | |
| How Color is Produced: | |
| Red Sectors Description: | |
| Where Color Attached: | |
| Form of Colored Glass: | |
| Lamp Description: | |
| Type of Illuminant: | |
| Number of Spare Lamps: | |
| Number of Spare Burners: | |
| Candle Power: |
| Compressed Gas |
| Gas Container: | A 50-4 |
| Compressed Gas Capacity: | 178 cu ft. |
| Compressed Gas Charge: | 225 lbs |
| How Supply Renewed: | By tenders |
| At What Intervals: | As required |
| Spare Containers: | None |
| Gas Light |
| Gas Light Kind: | Acetylene |
| Gas Light Number of Burners: | 1 |
| Kind of Burner: | Flat flame |
| Candlepower Per Burner: | 10 cp |
| Total Candlepower: | |
| Consumption Gas Burner Per Hour: | .5 cu. ft/ hour |
| Total Consumption Per Hour: | .5 cu ft. |
| How Gas Obtained: | From storage tanks |
| Occulting Light |
| Characteristic: | 1 sec light, 1 sec eclipse |
| Time Limit: | |
| Eclipse Type: | Valve |
| Size and Amplitude: | |
| Axis Rotation: | |
| Axis Relation: | |
| Screen Revolution: | |
| Screen Number: | |
| Screen Time: | |
| Screen Form: | |
| Screen Mounting: | |
| Screen Order: | |
| Screen Date: | |
| Valve Maker: | |
| Valve Pattern: | |
| Reliability: | Needs occasional adjustment |
| Fog Signal General |
| Fog Signal Kind: | Bell struck by machinery |
| Time to Start: | None |
| How Long Will Pressure Last: | Not at all |
| Manufacturer: | |
| Year of Manufacture: | |
| Characteristic: | 2 strokes every 5 sec. |
| Duplication: | None |
| Timing Device: | |
| If whistle, siren, or trumpet, Pressure at Which Blown: | |
| Height Above Water: | |
| Compass Direction: | |
| Location: | Bell in skeleton light tower, striking apparatus in concrete house adjoining tower. |
| Distance and Direction: | In tower |
| Water Supply: | None required |
| Reached from Lighthouse: | Lighthouse & bell are in same structure. |
| Description of Fog Signal Building: | Fog bell striking apparatus in small concrete bldg adjoining tower, bldg has tank room on outside with separate entrance. |
| Pressure And Recording Gauge: |
| Bell Signal |
| Weight: | 900 lbs |
| Metal: | Bell |
| Diameter: | 36" |
| Height: | 28" |
| Time: | Electrically oper'd app. & will run continuously. |
| Manufacturer: | General LH Depot. |
| Weights for Operation: |
| Healthfulness |
| General Opinion: | Healthy |
| Diseases: | None |
| Prevalency: | No |
| Local Causes: | No |
| Recommended Improvements: | No |