Report for Negro Point (New York) - 1915

General
District: 3rd
Inspector: Oscar C. Luther
Location: On point S end of Ward's Island. On island is state hospital for insane. Regular trips to & from island are made by steamer connected with hospital
Date of Report: 05/03/1915
Latitude: 40° 46' 52"
Longitude: 73° 55' 40"
Premises
Site: Deed from City of NY
Date of Reservation:
Date of Deed: 02/26/1905
Date of Permission:
Date of Lease:
Area of the Entire Site: 4,607.41 sq. ft.
Area Inclosed:
Character of Soil:
Distance of tower from Nearest High-Water Mark: 13'
Inclosures to Premises / Type of Fence: No fence
Wharf or Landing on Premises: Neither
Road to Land or Wharf Chararacter of and Distance:
Means to Reach Light Station: Boat. There is mail service maintained by messenger btwn hospital & main land. Address of Keeper, Hospital, Wards Island, NY.
Distance to Nearest Road:
Distance to Post Office:
Distance to Village:
Facilities for Public Conveyance:
Facilities for Private Conveyance:
Means Used for Support of Lantern: Tower
Number of Separate Lights: 1
First Built or Established: 1913
Last Rebuilt, Repaired, or Renovated: Never rebuilt
Condition at This Date:
Shape of Tower in Plan:
Form of Tower:
Height from Base to Ventilator Ball:
Height of Focal Plane Above Mean High Water: 34'
Background of Lighthouse as Seen from Sea: Bldgs in NY City
Color of Tower: Red
Color of Tower/ How Produced: Paint
Tower Connection: No keeper's dwelling at this station
Object of Navigation: Channel light, for general navigation.
Building Materials: Iron on concrete foundation
General Description:
Wall Thickness at Base:
Wall Thickness at Parapet:
Diameter at Base:
Diameter at Parapet:
Kind of Stairway and Steps: Iron steps
Number of Landings:
Size of Glass: No windows in tower
Number of Windows and Size of Sash:
Number of Doors:
Kind of Foundation and Depth Below Surface:
Character of Soil Surrounding the Lighthouse:
Soil Susceptibility:
Miscellaneous Remarks:
Lantern and Fixtures
Order of Lantern: 200 mm buoy lantern
Shape of Lantern:
Diameter to Glass:
Diameter in the Clear:
Number of Sides:
Type of Bars:
Thickness of Bars:
Height Glazed:
Number of Plates in Height:
Number of Plates Each Side:
Thickness of Plates:
Size of Plates:
Number of Storm Panes:
Unglazed Side of Lantern:
What Bearings:
Construction Material Lantern:
Construction Material Roof / Cowl:
Ventilator / Cowl:
Lightning Spindle:
Description of Lightning Rod:
Balustrade: Gallery around lantern.
Lantern Doors:
Floor of Lantern:
Watchroom Doors:
Parapet Diameter:
Watchroom
How is Watchroom Fitted: No watchroom. There is a small concrete house adjoining tower foundation used as watchroom for fog signal.
How is Relief Called:
Where is Call System Led:
Illuminating Apparatus
Kind of Apparatus:
Intensity in Candles: 70
Name of Maker:
Year Made:
Marks and Number: None
Order of Apparatus:
Inside Diameter:
Light Characteristic:
Time of Revolution:
Flash Interval:
Duration of Flash:
Arc of Each Fixed Part:
Number of Panels:
Number of Flash Panels:
Arc of Each:
Number of Elements in Central Drum:
Number of Prisms Above Center Drum:
Number of Prisms Below Center Drum:
Does Apparatus Revolve?: False
Is There a Revolving Belt?: False
Revolving Panels:
How Flash is Produced:
Number of Vertical Elements Panel:
Fixed Lens Covered:
Pedestal:
Service Table:
Draft Tube Description:
Revolving Machinery:
Standby and Description:
Chariot Float or Balls:
Chariot Description:
Length of Drop Tube:
Clock Weight:
Length of Winding Time:
Drive During Rewind:
Machinery Protection:
Regulated:
Lens Protection:
How Color is Produced:
Red Sectors Description:
Where Color Attached:
Form of Colored Glass:
Lamp Description:
Type of Illuminant:
Number of Spare Lamps:
Number of Spare Burners:
Candle Power:


Compressed Gas
Gas Container: A 50-4
Compressed Gas Capacity: 178 cu ft.
Compressed Gas Charge: 225 lbs
How Supply Renewed: By tenders
At What Intervals: As required
Spare Containers: None


Gas Light
Gas Light Kind: Acetylene
Gas Light Number of Burners: 1
Kind of Burner: Flat flame
Candlepower Per Burner: 10 cp
Total Candlepower:
Consumption Gas Burner Per Hour: .5 cu. ft/ hour
Total Consumption Per Hour: .5 cu ft.
How Gas Obtained: From storage tanks


Occulting Light
Characteristic: 1 sec light, 1 sec eclipse
Time Limit:
Eclipse Type: Valve
Size and Amplitude:
Axis Rotation:
Axis Relation:
Screen Revolution:
Screen Number:
Screen Time:
Screen Form:
Screen Mounting:
Screen Order:
Screen Date:
Valve Maker:
Valve Pattern:
Reliability: Needs occasional adjustment
Fog Signal General
Fog Signal Kind: Bell struck by machinery
Time to Start: None
How Long Will Pressure Last: Not at all
Manufacturer:
Year of Manufacture:
Characteristic: 2 strokes every 5 sec.
Duplication: None
Timing Device:
If whistle, siren, or trumpet, Pressure at Which Blown:
Height Above Water:
Compass Direction:
Location: Bell in skeleton light tower, striking apparatus in concrete house adjoining tower.
Distance and Direction: In tower
Water Supply: None required
Reached from Lighthouse: Lighthouse & bell are in same structure.
Description of Fog Signal Building: Fog bell striking apparatus in small concrete bldg adjoining tower, bldg has tank room on outside with separate entrance.
Pressure And Recording Gauge:
Bell Signal
Weight: 900 lbs
Metal: Bell
Diameter: 36"
Height: 28"
Time: Electrically oper'd app. & will run continuously.
Manufacturer: General LH Depot.
Weights for Operation:
Healthfulness
General Opinion: Healthy
Diseases: None
Prevalency: No
Local Causes: No
Recommended Improvements: No