Report for Laurel Point Light-Station (North Carolina) - 1909

General
District: 5th
Inspector: John Murdoch, Assistant Light-House Engineer
Location: Laurel Point, NC, about 1.25 miles NNE'ly from Laurel Point, S'ly side of the W'ly part of Albamarle Sound, NC.
Date of Report: 11/25/1909
Latitude: 36° 00' 15"
Longitude: 76° 23' 30"
Premises
Site: Submarine.
Date of Reservation:
Date of Deed:
Date of Permission:
Date of Lease:
Area of the Entire Site:
Area Inclosed:
Character of Soil:
Distance of tower from Nearest High-Water Mark:
Inclosures to Premises / Type of Fence:
Wharf or Landing on Premises:
Road to Land or Wharf Chararacter of and Distance:
Means to Reach Light Station: By railroad to Edenton, Steamer to station. (Gasoline Launch.)
Distance to Nearest Road: 10 miles to railroad station at Columbia, Tyrell County, NC.
Distance to Post Office: Columbia, 10 miles.
Distance to Village: Columbia, 10 Miles.
Facilities for Public Conveyance: None.
Facilities for Private Conveyance: Small boat 10 miles.
Means Used for Support of Lantern: Dwelling.
Number of Separate Lights: 1
First Built or Established: 1880
Last Rebuilt, Repaired, or Renovated: December, 1907
Condition at This Date: Good
Shape of Tower in Plan: Hexagonal structure.
Form of Tower: No tower.
Height from Base to Ventilator Ball:
Height of Focal Plane Above Mean High Water: 42 feet.
Background of Lighthouse as Seen from Sea: Water & sky.
Color of Tower: White; substructure brown.
Color of Tower/ How Produced: By paint.
Tower Connection:
Object of Navigation: Local Navigation.
Building Materials:
General Description:
Wall Thickness at Base:
Wall Thickness at Parapet:
Diameter at Base:
Diameter at Parapet:
Kind of Stairway and Steps: Wood
Number of Landings: 3
Size of Glass: 10" x 12" & 9" x 18.75"
Number of Windows and Size of Sash: 6 Windows 1st floor, 2'10.5" x 4' 8"; 2 2nd floor 2' x 3' 11"
Number of Doors: 16
Kind of Foundation and Depth Below Surface: Iron screwpile, 10 feet.
Character of Soil Surrounding the Lighthouse:
Soil Susceptibility:
Miscellaneous Remarks:
Lantern and Fixtures
Order of Lantern: 4th
Shape of Lantern: Polygonal
Diameter to Glass: 7'
Diameter in the Clear:
Number of Sides: 9
Type of Bars: Vertical
Thickness of Bars:
Height Glazed: 36"
Number of Plates in Height: 1
Number of Plates Each Side: 1
Thickness of Plates: 3/8"
Size of Plates: 36" x 28"
Number of Storm Panes: None
Unglazed Side of Lantern: None.
What Bearings:
Construction Material Lantern: Copper, iron & wood.
Construction Material Roof / Cowl: Copper.
Ventilator / Cowl: Copper.
Lightning Spindle: Brass.
Description of Lightning Rod: Copper, led over roof from sill of lantern to side of house and to water.
Balustrade: Wood
Lantern Doors: Wood, fitted with hinges to frame of lantern.
Floor of Lantern: Wood.
Watchroom Doors: None.
Parapet Diameter:
Ventilators
Location / Number: Lower portion of lantern.
Ladders / Cleaning Arrangement: None
Curtain Hooks / Hanger: Screwed into lantern.


Watchroom
How is Watchroom Fitted: None.
How is Relief Called:
Where is Call System Led:
Illuminating Apparatus
Kind of Apparatus: 4 hours.
Intensity in Candles:
Name of Maker: Barbier & Fenestre, Cons', A Paris
Year Made: 1877
Marks and Number: B.F./55
Order of Apparatus: 4th
Inside Diameter: 19.75"
Light Characteristic: Flashing white.
Time of Revolution: 3 minutes.
Flash Interval: 30 seconds.
Duration of Flash:
Arc of Each Fixed Part:
Number of Panels: 6
Number of Flash Panels: 6
Arc of Each:
Number of Elements in Central Drum: 3
Number of Prisms Above Center Drum: 6
Number of Prisms Below Center Drum: 4
Does Apparatus Revolve?: True
Is There a Revolving Belt?: False
Revolving Panels:
How Flash is Produced:
Number of Vertical Elements Panel:
Fixed Lens Covered:
Pedestal: Iron
Service Table: Wood trimming table, covered with zinc.
Draft Tube Description: None
Revolving Machinery: Made by Barbier & Fenestre, Paris.
Standby and Description:
Chariot Float or Balls: Chariot.
Chariot Description: 3 1/8" diameter hub wheel.
Length of Drop Tube: 18 feet
Clock Weight:
Length of Winding Time: 4 hours.
Drive During Rewind:
Machinery Protection: By galss casing.
Regulated: Fan governor.
Lens Protection:
How Color is Produced:
Red Sectors Description:
Where Color Attached:
Form of Colored Glass:
Lamp Description: Improved, 1 wick.
Type of Illuminant:
Number of Spare Lamps: 2 None.
Number of Spare Burners:
Candle Power:


Clock Cord Description
Revolving Cord:
Size of Clock Cord:
Length of Clock Cord:
How Led: Through center of house.
Diameter and Length of Clock Drum:
Closets and Store Rooms
Tower Closet Use:
Oil House Description: On 1st floor; oilstand covered with zinc.
Oil House Inside Dimension:
Oil House Construction Material:
Oil House Capacity:
Other (Describe): On 1st floor; fitted with shelves, for general purposes.
Suitability: Dry & suitable.
Fog Signal General
Fog Signal Kind: Custer bell machine.
Time to Start: 1 minute.
How Long Will Pressure Last:
Manufacturer: J.D. Custer Co., Boston, Mass.
Year of Manufacture: 1855 (#45)
Characteristic: Single blow every 10 seconds.
Duplication: None.
Timing Device:
If whistle, siren, or trumpet, Pressure at Which Blown:
Height Above Water:
Compass Direction:
Location:
Distance and Direction:
Water Supply:
Reached from Lighthouse:
Description of Fog Signal Building:
Pressure And Recording Gauge:
Bell Signal
Weight: 1200
Metal: Bell metal
Diameter: 38"
Height: 30"
Time: 4 hours
Manufacturer:
Weights for Operation:
Dwelling
Location: No tower.
Coloring: White
Construction Materials: Wood.
Number of Rooms: 6
Number of Dwellings:
Heating Plant:
Number of Keepers: 1 keeper & 1 assistant.
Furnished Quarters:
NOT Furnished Quarters:
Outhouses:
Outhouse Coloring:
Paths and Walks:
Area Inclosed:
Area of Garden:
Area Timber or Shrubbery:
Cultivation Area Available:
Area Cultivated:
Character of Surroundings:
Stove, Maker:
Stove, Size:
Sink, Maker:
Sink, Size:
Pump, Maker:
Pump, Size:
Lamps:
Water
How Procured: From roof.
Quality: Good.
Quantity: Ample
Injury Possible: Not liable.
Purity Precaution: Tanks cleaned twice each year.
Tank Capacity: 4 tanks, 200 galls. each, on 1st floor.
Tank Material: Iron.
Distilling Apparatus: False
Distilling Manufacturer:
Well Description:
Well Diameter:
Well Lining:
Pump or Bucket:
What Power Used:
Distance from Dwelling:
Healthfulness
General Opinion: Generally healthy.
Diseases: Malarial.
Prevalency: Spring & fall.
Local Causes: Swampsp & marshes.
Recommended Improvements: No.