Report for Horseshoe Range West Group Lower Front (white) (Pennsylvania) - 1911
| General |
| District: | 4th |
| Inspector: | Thos. J. Rout, Jr., Supt. |
| Location: | On bank of Fort Mifflin Naval Reservation, PA. |
| Date of Report: | 03/12/1911 |
| Latitude: | 39° 52' 59" |
| Longitude: | 75° 12' 13" |
| Premises |
| Site: | Naval Reservation |
| Date of Reservation: | |
| Date of Deed: | |
| Date of Permission: | 11/07/1880 |
| Date of Lease: | |
| Area of the Entire Site: | About 8 acres |
| Area Inclosed: | About 6 acres |
| Character of Soil: | |
| Distance of tower from Nearest High-Water Mark: | About 3' |
| Inclosures to Premises / Type of Fence: | Board & wire fence |
| Wharf or Landing on Premises: | None |
| Road to Land or Wharf Chararacter of and Distance: | |
| Means to Reach Light Station: | By boat or trolley from Phila. to Penrose Ferry Bridge, thence walk to station. |
| Distance to Nearest Road: | |
| Distance to Post Office: | Paschallville, 3.5 miles |
| Distance to Village: | |
| Facilities for Public Conveyance: | |
| Facilities for Private Conveyance: | |
| Means Used for Support of Lantern: | Tower |
| Number of Separate Lights: | 1 light on tower, but there are 3 in this group |
| First Built or Established: | 1881 |
| Last Rebuilt, Repaired, or Renovated: | 1911 |
| Condition at This Date: | |
| Shape of Tower in Plan: | |
| Form of Tower: | |
| Height from Base to Ventilator Ball: | |
| Height of Focal Plane Above Mean High Water: | 40' |
| Background of Lighthouse as Seen from Sea: | Bldgs & trees |
| Color of Tower: | White |
| Color of Tower/ How Produced: | Paint |
| Tower Connection: | Detached |
| Object of Navigation: | Channel & range - general navigation |
| Building Materials: | Structural steel |
| General Description: | |
| Wall Thickness at Base: | |
| Wall Thickness at Parapet: | |
| Diameter at Base: | |
| Diameter at Parapet: | |
| Kind of Stairway and Steps: | Iron ladder |
| Number of Landings: | |
| Size of Glass: | No windows |
| Number of Windows and Size of Sash: | No windows |
| Number of Doors: | None in tower; concrete base has 2 - 2' 8" x 6' 8" doors. |
| Kind of Foundation and Depth Below Surface: | |
| Character of Soil Surrounding the Lighthouse: | |
| Soil Susceptibility: | |
| Miscellaneous Remarks: | Tower is 23' high & rests on concrete base in which gas tanks are housed. Tower is of skeleton steel construction, slatted on channel face. |
| Lantern and Fixtures |
| Order of Lantern: | Similar to locomotive headlight lantern |
| Shape of Lantern: | Cylindrical |
| Diameter to Glass: | 14" |
| Diameter in the Clear: | |
| Number of Sides: | |
| Type of Bars: | None |
| Thickness of Bars: | |
| Height Glazed: | |
| Number of Plates in Height: | |
| Number of Plates Each Side: | |
| Thickness of Plates: | |
| Size of Plates: | |
| Number of Storm Panes: | |
| Unglazed Side of Lantern: | Only 1 side of lantern is glazed, this faces down range. |
| What Bearings: | |
| Construction Material Lantern: | Metal & glass |
| Construction Material Roof / Cowl: | |
| Ventilator / Cowl: | None |
| Lightning Spindle: | None |
| Description of Lightning Rod: | |
| Balustrade: | Steel platform & railing around lantern. |
| Lantern Doors: | Hung on hinges & provided with latch. |
| Floor of Lantern: | Metal |
| Watchroom Doors: | None |
| Parapet Diameter: |
| Illuminating Apparatus |
| Kind of Apparatus: | |
| Intensity in Candles: | 3700 |
| Name of Maker: | American Gas Accumulator Co. |
| Year Made: | 1911 |
| Marks and Number: | None |
| Order of Apparatus: | Reflector light |
| Inside Diameter: | No central drum |
| Light Characteristic: | |
| Time of Revolution: | Not revolving |
| Flash Interval: | |
| Duration of Flash: | |
| Arc of Each Fixed Part: | |
| Number of Panels: | No lens |
| Number of Flash Panels: | |
| Arc of Each: | |
| Number of Elements in Central Drum: | |
| Number of Prisms Above Center Drum: | |
| Number of Prisms Below Center Drum: | |
| Does Apparatus Revolve?: | False |
| Is There a Revolving Belt?: | False |
| Revolving Panels: | |
| How Flash is Produced: | |
| Number of Vertical Elements Panel: | |
| Fixed Lens Covered: | |
| Pedestal: | |
| Service Table: | |
| Draft Tube Description: | |
| Revolving Machinery: | |
| Standby and Description: | |
| Chariot Float or Balls: | |
| Chariot Description: | |
| Length of Drop Tube: | |
| Clock Weight: | |
| Length of Winding Time: | |
| Drive During Rewind: | |
| Machinery Protection: | |
| Regulated: | |
| Lens Protection: | |
| How Color is Produced: | |
| Red Sectors Description: | |
| Where Color Attached: | |
| Form of Colored Glass: | |
| Lamp Description: | |
| Type of Illuminant: | Acetylene |
| Number of Spare Lamps: | |
| Number of Spare Burners: | |
| Candle Power: | Burner is 30 cp; apparatus is 3700 cp |
| Compressed Gas |
| Gas Container: | 3- A50 tanks (9" x 6') are in service at 1 time. |
| Compressed Gas Capacity: | 177 cu. ft. |
| Compressed Gas Charge: | 160 lbs |
| How Supply Renewed: | By having tanks recharged. |
| At What Intervals: | About 4 months |
| Spare Containers: | 3 |
| Gas Light |
| Gas Light Kind: | Acetylene gas |
| Gas Light Number of Burners: | 1 burner |
| Kind of Burner: | 3/4 cu ft. |
| Candlepower Per Burner: | 30 |
| Total Candlepower: | |
| Consumption Gas Burner Per Hour: | 3/10 cu ft. |
| Total Consumption Per Hour: | |
| How Gas Obtained: | From 4 A-50 AGA tanks |
| Occulting Light |
| Characteristic: | White 4/10 sec; eclipse 6/10 sec |
| Time Limit: | Any desired characteristic may be obtained. |
| Eclipse Type: | Valve |
| Size and Amplitude: | |
| Axis Rotation: | |
| Axis Relation: | |
| Screen Revolution: | |
| Screen Number: | |
| Screen Time: | |
| Screen Form: | |
| Screen Mounting: | |
| Screen Order: | |
| Screen Date: | |
| Valve Maker: | AGA Co |
| Valve Pattern: | Standard pattern |
| Reliability: | Yes |
| Parabolic Mirror |
| Parabolic Opening: | |
| Parabolic Mirror Depth: | |
| Parabolic Focal Length: | |
| Parabolic Material: | Apparatus is a Mougin mirror, glass. |
| Closets and Store Rooms |
| Tower Closet Use: | |
| Oil House Description: | When base was constructed, a compartment was set aside to serve as oil room. It has a hinged door. |
| Oil House Inside Dimension: | About 3' x 10' |
| Oil House Construction Material: | Concrete |
| Oil House Capacity: | 40 cases - 200 gal. |
| Other (Describe): | |
| Suitability: |