Report for South Pass East Jetty (Louisiana) - 1911

General
District: 8th
Inspector: Comdr. C.P. Eaton, USN, Supt; Thos. Brown Supt.
Location: Near outer end of E Jetty at mouth of S Pass of Mississippi River, LA.
Date of Report: 07/29/1911
Latitude: 28° 59' 27"
Longitude: 89° 08' 10"
Premises
Site: Submarine
Date of Reservation:
Date of Deed:
Date of Permission:
Date of Lease:
Area of the Entire Site:
Area Inclosed:
Character of Soil:
Distance of tower from Nearest High-Water Mark: In water
Inclosures to Premises / Type of Fence:
Wharf or Landing on Premises: Landing at boathouse 1400' from tower
Road to Land or Wharf Chararacter of and Distance:
Means to Reach Light Station: By boat
Distance to Nearest Road:
Distance to Post Office: Port Eads, LA., 1/2 mile.
Distance to Village:
Facilities for Public Conveyance:
Facilities for Private Conveyance:
Means Used for Support of Lantern: Wooden tower on iron piles
Number of Separate Lights: 1
First Built or Established: 1878
Last Rebuilt, Repaired, or Renovated: Rebuilt 1891; Repaired 1911
Condition at This Date:
Shape of Tower in Plan:
Form of Tower:
Height from Base to Ventilator Ball:
Height of Focal Plane Above Mean High Water: 52'
Background of Lighthouse as Seen from Sea: Sky
Color of Tower: White
Color of Tower/ How Produced: Paint
Tower Connection: On top
Object of Navigation: To mark outer end of E Jetty. For general & local navigation.
Building Materials: Foundation, iron piles, superstructure, wood
General Description:
Wall Thickness at Base:
Wall Thickness at Parapet:
Diameter at Base:
Diameter at Parapet:
Kind of Stairway and Steps: Spiral wood
Number of Landings:
Size of Glass: Quadrants 10.5"; Rad. 10" x 16"
Number of Windows and Size of Sash: 4 circular 21" dia.; 6 - 10" x 16" 4 lts double sash
Number of Doors: 2 - 3' x 7'
Kind of Foundation and Depth Below Surface:
Character of Soil Surrounding the Lighthouse:
Soil Susceptibility:
Miscellaneous Remarks:
Lantern and Fixtures
Order of Lantern: 5th
Shape of Lantern: Polygonal
Diameter to Glass: 85"
Diameter in the Clear:
Number of Sides: 8
Type of Bars: Vertical
Thickness of Bars:
Height Glazed: 36"
Number of Plates in Height: One
Number of Plates Each Side: One
Thickness of Plates: 1/4"
Size of Plates: 34" x 36"
Number of Storm Panes:
Unglazed Side of Lantern:
What Bearings:
Construction Material Lantern: Iron & glass
Construction Material Roof / Cowl: Iron
Ventilator / Cowl: Copper
Lightning Spindle: Yes
Description of Lightning Rod:
Balustrade: Wooden
Lantern Doors: 1 in parapet
Floor of Lantern: Wood
Watchroom Doors: Trap door in lantern floor
Parapet Diameter:
Ventilators
Location / Number: 4 in parapet walls
Ladders / Cleaning Arrangement: Not needed
Curtain Hooks / Hanger: Yes, fitted to base of dome.


Watchroom
How is Watchroom Fitted: With service table
How is Relief Called:
Where is Call System Led:
Illuminating Apparatus
Kind of Apparatus:
Intensity in Candles: 144
Name of Maker:
Year Made:
Marks and Number:
Order of Apparatus: 5th
Inside Diameter: 14 3/4"
Light Characteristic:
Time of Revolution:
Flash Interval:
Duration of Flash:
Arc of Each Fixed Part:
Number of Panels: 4
Number of Flash Panels:
Arc of Each:
Number of Elements in Central Drum: 1
Number of Prisms Above Center Drum: 7
Number of Prisms Below Center Drum: 5
Does Apparatus Revolve?: False
Is There a Revolving Belt?: False
Revolving Panels:
How Flash is Produced:
Number of Vertical Elements Panel:
Fixed Lens Covered:
Pedestal: Iron
Service Table:
Draft Tube Description: Not needed
Revolving Machinery:
Standby and Description:
Chariot Float or Balls:
Chariot Description:
Length of Drop Tube:
Clock Weight:
Length of Winding Time:
Drive During Rewind:
Machinery Protection:
Regulated:
Lens Protection: Linen
How Color is Produced: By chimney (red)
Red Sectors Description:
Where Color Attached:
Form of Colored Glass:
Lamp Description: 5th order
Type of Illuminant: Oil
Number of Spare Lamps: 1
Number of Spare Burners: 1
Candle Power: 38 cp


Vapor Oil Lamp
Number of Wicks or Mantels: 1 wick
Diameter of Outside Wick:
Diameter of Mantel:
Diameter of Circum Circle:
Closets and Store Rooms
Tower Closet Use: 2, fitted with shelves & used as pantry & storeroom
Oil House Description: In lower floor of fog bell tower
Oil House Inside Dimension: 12 x 12 x 10
Oil House Construction Material: Wood
Oil House Capacity: About 1200 cans as part of space is used for other purposes.
Other (Describe): Storerooms in lower part of fog bell tower fitted with shelves.
Suitability: Suited for purposes.
Fog Signal General
Fog Signal Kind: Bell, Gamewell
Time to Start:
How Long Will Pressure Last:
Manufacturer:
Year of Manufacture:
Characteristic: 1 stroke every 10 sec.
Duplication:
Timing Device:
If whistle, siren, or trumpet, Pressure at Which Blown:
Height Above Water:
Compass Direction:
Location: Adjacent to lighthouse, about 50' from river.
Distance and Direction: Attached
Water Supply: None needed
Reached from Lighthouse:
Description of Fog Signal Building: Wooden bldg with oil stored on lower floor. 1 stove, gable, roof, with 2 story addition of 1 room in which is placed bell machinery.
Pressure And Recording Gauge:
Bell Signal
Weight:
Metal: Bronze
Diameter: 38.5"
Height: 27.5"
Time: 3 hrs
Manufacturer: Gamewell Fire Alarm Co., Boston, Mass.
Weights for Operation:
Dwelling
Location: In tower
Coloring: White with green blinds
Construction Materials: Foundation, iron piles, superstructure, wood
Number of Rooms: 4
Number of Dwellings:
Heating Plant:
Number of Keepers: 1 Keeper, 1 Assistant
Furnished Quarters:
NOT Furnished Quarters:
Outhouses:
Outhouse Coloring:
Paths and Walks: Plank walk on Jetty, 1400' long to boathouse.
Area Inclosed:
Area of Garden:
Area Timber or Shrubbery:
Cultivation Area Available: None
Area Cultivated:
Character of Surroundings:
Stove, Maker: G. F. Filley, Charter Oak
Stove, Size: No. 1117
Sink, Maker:
Sink, Size: 16 x 27
Pump, Maker:
Pump, Size:
Lamps: 1 Funck table lamp, 2 hand lamps
Water
How Procured: Rain
Quality: Good
Quantity: Ample
Injury Possible: Not liable
Purity Precaution: Tops covered
Tank Capacity: 3200 gals on gallery
Tank Material: 2, cypress
Distilling Apparatus: False
Distilling Manufacturer:
Well Description:
Well Diameter:
Well Lining:
Pump or Bucket:
What Power Used:
Distance from Dwelling:
Healthfulness
General Opinion: Good
Diseases: Malarial fever
Prevalency: Summer
Local Causes:
Recommended Improvements: No
Miscellaneous
Access to Lighthouse: Landing at boathouse 116" x 30" located in water on W'ly side of E Jetty. Plank walk extends along on top of Jetty from tower to boathouse.
Distance and Direction: Boathouse 1400' N'ly from tower.
Miscellaneous Remarks: Station in good condition.
Boats
Boat Number: 48
Type: Yawl
Length: 4' 4"
Width: 15'
When Built: 1893
Date Harbored at Station:
Sails: False
Suited to Work: Fairly