Report for South Buffalo North Side Light (New York) - 1909
| General |
| District: | 10th |
| Inspector: | Chas. Bartlett, Chief Clerk and Norris Works, Supt |
| Location: | On S end of S Harbor Section of Breakwater |
| Date of Report: | 02/03/1909 |
| Latitude: | 42° 50' 08" |
| Longitude: | 78° 52' 05" |
| Premises |
| Site: | On US Breakwater Reservation |
| Date of Reservation: | |
| Date of Deed: | 09/12/1900 |
| Date of Permission: | |
| Date of Lease: | |
| Area of the Entire Site: | 1872 sq. ft. No particular area reserved, occupies "L" at end of breakwater. |
| Area Inclosed: | |
| Character of Soil: | |
| Distance of tower from Nearest High-Water Mark: | |
| Inclosures to Premises / Type of Fence: | |
| Wharf or Landing on Premises: | On breakwater |
| Road to Land or Wharf Chararacter of and Distance: | |
| Means to Reach Light Station: | By boat from S side Beacon, 600' |
| Distance to Nearest Road: | |
| Distance to Post Office: | Free delivery from Buffalo, NY twice per day. 1.5 miles to W Seneca PO from dwelling. |
| Distance to Village: | |
| Facilities for Public Conveyance: | |
| Facilities for Private Conveyance: | |
| Means Used for Support of Lantern: | Bottle shaped structure with hoisting apparatus & lens lantern |
| Number of Separate Lights: | 1 |
| First Built or Established: | 1903 |
| Last Rebuilt, Repaired, or Renovated: | |
| Condition at This Date: | Good |
| Shape of Tower in Plan: | Circular |
| Form of Tower: | Bottle shaped. |
| Height from Base to Ventilator Ball: | 24' to focal plane |
| Height of Focal Plane Above Mean High Water: | 36' 3" |
| Background of Lighthouse as Seen from Sea: | Low, flat shore covered with blast furnaces & rolling mills, which emit dark smoke. |
| Color of Tower: | White |
| Color of Tower/ How Produced: | Lead & oil paint |
| Tower Connection: | Dwelling, 1 mile distant on shore. |
| Object of Navigation: | Marks N side of S entrance to Outer Harbor. |
| Building Materials: | Boiler plate |
| General Description: | 3/8" boiler plate cyl 10' 3/4" dia, 8' high, bolted to concrete foundation, & prov. w/ curved iron door, & 4 circ. windows, forms base of structure. Roofed w/ 3/8" boiler plate dome, from ctr of which rises a 1/4" boiler plate col., 2' 3" dia. |
| Wall Thickness at Base: | 3/8" |
| Wall Thickness at Parapet: | 1/4" |
| Diameter at Base: | 10' 3/4" |
| Diameter at Parapet: | 2' 3" |
| Kind of Stairway and Steps: | Cable, pulley & hoisting winch. Outside ladder. |
| Number of Landings: | |
| Size of Glass: | 14" dia. 1/4" plate glass |
| Number of Windows and Size of Sash: | 4 - bronze sash in cast iron circular windows. |
| Number of Doors: | 1 |
| Kind of Foundation and Depth Below Surface: | Concrete to mean lake level, resting on stone crib filling, in stone & gravel filling to rock. |
| Character of Soil Surrounding the Lighthouse: | |
| Soil Susceptibility: | |
| Miscellaneous Remarks: | Total height 23' 3/4". Egg shaped vent. ball on roof supported 22.5" above top of col. by 4 slight posts, leaving open space for exposure of lens lantern, which is hoisted btwn guides, rising inside col. from top of service table, by means of cable. |
| Lantern and Fixtures |
| Order of Lantern: | No lantern |
| Shape of Lantern: | |
| Diameter to Glass: | |
| Diameter in the Clear: | |
| Number of Sides: | |
| Type of Bars: | |
| Thickness of Bars: | |
| Height Glazed: | |
| Number of Plates in Height: | |
| Number of Plates Each Side: | |
| Thickness of Plates: | |
| Size of Plates: | |
| Number of Storm Panes: | |
| Unglazed Side of Lantern: | Open on all sides. |
| What Bearings: | |
| Construction Material Lantern: | |
| Construction Material Roof / Cowl: | 3/8" boiler plate. |
| Ventilator / Cowl: | Egg shaped vent. ball on roof supported 22.5" above top of col. by 4 slight posts |
| Lightning Spindle: | Brass 22" long, bolted to top of hood. |
| Description of Lightning Rod: | No lightning conductor provided, structure is iron, bolted to concrete base. |
| Balustrade: | Outside fixed ladder to give access to top when necessary. |
| Lantern Doors: | |
| Floor of Lantern: | |
| Watchroom Doors: | |
| Parapet Diameter: |
| Ventilators |
| Location / Number: | Ventilator holes thru base of hood. |
| Ladders / Cleaning Arrangement: | |
| Curtain Hooks / Hanger: |
| Illuminating Apparatus |
| Kind of Apparatus: | |
| Intensity in Candles: | |
| Name of Maker: | Barbier, Benard & Turenne |
| Year Made: | Installed 1903 |
| Marks and Number: | |
| Order of Apparatus: | 6th order lens lantern |
| Inside Diameter: | 11 3/4" |
| Light Characteristic: | Fixed white |
| Time of Revolution: | |
| Flash Interval: | |
| Duration of Flash: | |
| Arc of Each Fixed Part: | 360 degrees |
| Number of Panels: | 4 |
| Number of Flash Panels: | |
| Arc of Each: | 90 degrees |
| Number of Elements in Central Drum: | 1 |
| Number of Prisms Above Center Drum: | 3 |
| Number of Prisms Below Center Drum: | 3 |
| Does Apparatus Revolve?: | False |
| Is There a Revolving Belt?: | False |
| Revolving Panels: | |
| How Flash is Produced: | |
| Number of Vertical Elements Panel: | |
| Fixed Lens Covered: | |
| Pedestal: | Lens stands on top of iron service table & cupboard when lowered into structure, 30" high. |
| Service Table: | Top of iron cupboard, 30" x 24" |
| Draft Tube Description: | Not required |
| Revolving Machinery: | |
| Standby and Description: | |
| Chariot Float or Balls: | |
| Chariot Description: | |
| Length of Drop Tube: | |
| Clock Weight: | |
| Length of Winding Time: | |
| Drive During Rewind: | |
| Machinery Protection: | |
| Regulated: | |
| Lens Protection: | |
| How Color is Produced: | |
| Red Sectors Description: | |
| Where Color Attached: | |
| Form of Colored Glass: | |
| Lamp Description: | 5th order, tank, with cap. for 5-day supply of oil, on top of lens. |
| Type of Illuminant: | |
| Number of Spare Lamps: | 2 |
| Number of Spare Burners: | None |
| Candle Power: |
| Vapor Oil Lamp |
| Number of Wicks or Mantels: | 1 round wick |
| Diameter of Outside Wick: | 1 1/4" |
| Diameter of Mantel: | |
| Diameter of Circum Circle: |
| Closets and Store Rooms |
| Tower Closet Use: | Iron closet & service table in base of structure. |
| Oil House Description: | In basement of S side tower. |
| Oil House Inside Dimension: | |
| Oil House Construction Material: | |
| Oil House Capacity: | |
| Other (Describe): | |
| Suitability: | Dry, suited |
| Healthfulness |
| General Opinion: | Healthful |
| Diseases: | |
| Prevalency: | |
| Local Causes: | |
| Recommended Improvements: |
| Miscellaneous |
| Access to Lighthouse: | Breakwater, iron ladder. |
| Distance and Direction: | |
| Miscellaneous Remarks: |