Report for Sequin (Maine) - 1936
General |
District: | 1st |
Inspector: | Thomas Sampson, Asst. Superintendent |
Location: | On highest part of Sequin Island, off the seacoast of ME., & about 2 miles off the S of the mouth of the Kennebec River. |
Date of Report: | 05/09/1936 |
Latitude: | 43° 42' 27N" |
Longitude: | 69° 45' 32W" |
Premises |
Site: | Conveyed by Commonwealth of Massachusetts |
Date of Reservation: | |
Date of Deed: | 03/20/1797 |
Date of Permission: | |
Date of Lease: | |
Area of the Entire Site: | Whole Island |
Area Inclosed: | 212 acres |
Character of Soil: | |
Distance of tower from Nearest High-Water Mark: | About 700' - 900 to boatslip |
Inclosures to Premises / Type of Fence: | |
Wharf or Landing on Premises: | Boatslip |
Road to Land or Wharf Chararacter of and Distance: | |
Means to Reach Light Station: | Boat |
Distance to Nearest Road: | |
Distance to Post Office: | |
Distance to Village: | |
Facilities for Public Conveyance: | |
Facilities for Private Conveyance: | |
Means Used for Support of Lantern: | Tower |
Number of Separate Lights: | One |
First Built or Established: | 1795 |
Last Rebuilt, Repaired, or Renovated: | 1857 |
Condition at This Date: | |
Shape of Tower in Plan: | |
Form of Tower: | |
Height from Base to Ventilator Ball: | |
Height of Focal Plane Above Mean High Water: | 180' |
Background of Lighthouse as Seen from Sea: | Sky |
Color of Tower: | White |
Color of Tower/ How Produced: | Whitewash |
Tower Connection: | Connected by workroom |
Object of Navigation: | Seacoast |
Building Materials: | Granite & brick |
General Description: | |
Wall Thickness at Base: | |
Wall Thickness at Parapet: | |
Diameter at Base: | |
Diameter at Parapet: | |
Kind of Stairway and Steps: | Iron circular |
Number of Landings: | |
Size of Glass: | 10 3/8" x 16 3/8" |
Number of Windows and Size of Sash: | 2 - 23" x 34 3/4" |
Number of Doors: | 2; 1- 4' x 7' 6", 1 - 3' x 7' 0" |
Kind of Foundation and Depth Below Surface: | |
Character of Soil Surrounding the Lighthouse: | |
Soil Susceptibility: | |
Miscellaneous Remarks: | 1st conveyance act Feb. 19, 1794 |
Lantern and Fixtures |
Order of Lantern: | 1st |
Shape of Lantern: | Polygonal |
Diameter to Glass: | |
Diameter in the Clear: | |
Number of Sides: | |
Type of Bars: | Vertical |
Thickness of Bars: | |
Height Glazed: | 9' 6" |
Number of Plates in Height: | 3 |
Number of Plates Each Side: | 3 |
Thickness of Plates: | 5/16" (in office) |
Size of Plates: | |
Number of Storm Panes: | |
Unglazed Side of Lantern: | None |
What Bearings: | |
Construction Material Lantern: | Iron |
Construction Material Roof / Cowl: | Iron - dome shape roof |
Ventilator / Cowl: | Iron 18" diam. |
Lightning Spindle: | Fork end - copper - screwed to ball |
Description of Lightning Rod: | |
Balustrade: | 2 iron rails with 14 ball posts - granite gallery |
Lantern Doors: | None |
Floor of Lantern: | Granite - watchroom & service room iron |
Watchroom Doors: | None - open stairs |
Parapet Diameter: |
Ventilators |
Location / Number: | Parapet |
Ladders / Cleaning Arrangement: | 6' step ladder |
Curtain Hooks / Hanger: | Hung to cross beam - rollers |
Watchroom |
How is Watchroom Fitted: | Open room |
How is Relief Called: | |
Where is Call System Led: |
Illuminating Apparatus |
Kind of Apparatus: | |
Intensity in Candles: | 22,000 |
Name of Maker: | Henry LePaute, Paris |
Year Made: | Not known |
Marks and Number: | None |
Order of Apparatus: | 1st |
Inside Diameter: | 6' 0" |
Light Characteristic: | |
Time of Revolution: | |
Flash Interval: | |
Duration of Flash: | |
Arc of Each Fixed Part: | 360 degrees |
Number of Panels: | 8 |
Number of Flash Panels: | |
Arc of Each: | |
Number of Elements in Central Drum: | 17 |
Number of Prisms Above Center Drum: | 13 |
Number of Prisms Below Center Drum: | 6 |
Does Apparatus Revolve?: | False |
Is There a Revolving Belt?: | False |
Revolving Panels: | |
How Flash is Produced: | |
Number of Vertical Elements Panel: | |
Fixed Lens Covered: | |
Pedestal: | Iron 5' high - 5' 4" |
Service Table: | |
Draft Tube Description: | 3 pieces 5" stove pipe 3' long resting in lantern spider |
Revolving Machinery: | |
Standby and Description: | |
Chariot Float or Balls: | |
Chariot Description: | |
Length of Drop Tube: | |
Clock Weight: | |
Length of Winding Time: | |
Drive During Rewind: | |
Machinery Protection: | |
Regulated: | |
Lens Protection: | Linen cover |
How Color is Produced: | |
Red Sectors Description: | |
Where Color Attached: | |
Form of Colored Glass: | |
Lamp Description: | I.O.V. 55 mm. Type A |
Type of Illuminant: | Kerosene |
Number of Spare Lamps: | 2 |
Number of Spare Burners: | 2 |
Candle Power: | 1,500 cp |
Vapor Oil Lamp |
Number of Wicks or Mantels: | |
Diameter of Outside Wick: | |
Diameter of Mantel: | 55 mm. |
Diameter of Circum Circle: |
Closets and Store Rooms |
Tower Closet Use: | |
Oil House Description: | Red brick oil house NW of tower |
Oil House Inside Dimension: | 9' 9" x 14' 10" |
Oil House Construction Material: | Brick |
Oil House Capacity: | 3,000 gals - station fitted with 3 - 2020 gal. tanks for fuel oil |
Other (Describe): | Closet in workroom fitted with shelves used for spare burners, cleaning material, etc. |
Suitability: | Dry & suitable |
Fog Signal General |
Fog Signal Kind: | Air Diaphone |
Time to Start: | 15 min. |
How Long Will Pressure Last: | 2 blasts |
Manufacturer: | |
Year of Manufacture: | |
Characteristic: | Blast 1.5 sec; silent 1 sec; blast 1.5 sec.; silent 16 sec. |
Duplication: | The entire outfit |
Timing Device: | Belt driven |
If whistle, siren, or trumpet, Pressure at Which Blown: | 30 lbs |
Height Above Water: | About 160' |
Compass Direction: | S - 170 degrees true |
Location: | Guide to Kennebec River & general coast guide |
Distance and Direction: | About 250' S |
Water Supply: | Rain water |
Reached from Lighthouse: | Path |
Description of Fog Signal Building: | White brick fog signal building with lead colored trimmings |
Pressure And Recording Gauge: | Pressure gauge to 2 air tanks |
Bell Signal |
Weight: | 3,000 lbs |
Metal: | Iron |
Diameter: | 3' 8" |
Height: | 3' 3" |
Time: | |
Manufacturer: | Naylor-Vickers & Co., 1858 |
Weights for Operation: |
Siren Signal |
Siren: | Air Diaphone |
Siren Diameter: | |
Siren Built Date: | |
Siren Manufacturer: | Diaphone Co., limited of Canada |
Siren Ports: | |
Siren Revolutions: | |
Siren Governor: | Belt driven timing device |
Siren Condition: |
Internal Combustion Signal |
Fog Signal Kind: | |
Internal Combustion Kind: | Oil Engine |
Internal Combustion Manufacturer: | Chicago Pneumatic Tool Co. |
Internal Combustion Date: | Jan. 1923 |
Internal Combustion Size: | 10.5" x 8" x 10" |
Internal Combustion Horsepower: | 28 |
Internal Combustion Fuel: | Distillate |
Internal Combustion Starter: | Compressed air |
Compressor Maker: | Same |
Compressor Seat: | On same rod & bed |
Compressor Machinery: | |
Compressor Diameter: | 10" |
Compressor Stroke: | 8" |
Compressor RPMs: | 280 |
Character of Air Inlet: | Simplate |
Kind of Unloader: | Simplate C.P.T. Co. |
Diameter of Delivery Pipe: | 4" |
Air Receiver |
Number: | 2 |
Diameter: | 6' 0" |
Height: | 7' 6" |
Capacity Cubic Feet: | |
Pressure in Each: | 40 lbs |
Make of Reducing Valve: | |
Remarks: |
Dwelling |
Location: | Double dwelling connected with tower; Single dwelling about 50' S of tower |
Coloring: | White |
Construction Materials: | Double house - brick - single, wood. |
Number of Rooms: | 6 in each part of double, 7 in single |
Number of Dwellings: | 3 |
Heating Plant: | Hot water, Gurney, in double house only |
Number of Keepers: | Keeper & 2 assts. |
Furnished Quarters: | All |
NOT Furnished Quarters: | None |
Outhouses: | 5 |
Outhouse Coloring: | White |
Paths and Walks: | 4 paths - 4 walks |
Area Inclosed: | |
Area of Garden: | |
Area Timber or Shrubbery: | |
Cultivation Area Available: | None |
Area Cultivated: | None |
Character of Surroundings: | Rocky |
Stove, Maker: | Portland S.F. Co. (3) |
Stove, Size: | Royal Atlantic # 8 (3) |
Sink, Maker: | |
Sink, Size: | 39" x 20" x 5" (3) |
Pump, Maker: | Douglass (3) |
Pump, Size: | #2 (3) |
Lamps: |
Water |
How Procured: | Rain water from roof of buildings |
Quality: | Good |
Quantity: | Generally ample |
Injury Possible: | No |
Purity Precaution: | Frequent cleaning of cisterns |
Tank Capacity: | 61,000 gal - 9 cisterns - 2 in double dwelling, 1 in single, 2 in fog signal house; 4 outside |
Tank Material: | Stone & brick |
Distilling Apparatus: | False |
Distilling Manufacturer: | |
Well Description: | |
Well Diameter: | |
Well Lining: | |
Pump or Bucket: | Pump |
What Power Used: | Compressed air |
Distance from Dwelling: |
Healthfulness |
General Opinion: | Very healthful |
Diseases: | None |
Prevalency: | No |
Local Causes: | No |
Recommended Improvements: | No |
Miscellaneous |
Access to Lighthouse: | Boatslip to boathouse - path from lighthouse |
Distance and Direction: | 800' ENE |
Miscellaneous Remarks: |
Boats |
Boat #1 | |
Boat Number: | 106 |
Type: | Motor Boat |
Length: | 7' 3" |
Width: | 23' |
When Built: | |
Date Harbored at Station: | Jan. 1923 |
Sails: | False |
Suited to Work: | Yes |
Boat #2 | |
Boat Number: | 48 |
Type: | Rowboat |
Length: | 4' 9" |
Width: | 13' 6" |
When Built: | |
Date Harbored at Station: | No record |
Sails: | False |
Suited to Work: | Yes |
Power Boat |
Engine Type: | Mianus |
Horsepower: | 7.5 |
Engine Maker: | Mianus Motor Co. |
Spare Coil: | |
Magnet: | |
Battery: | Dry |
Propeller Diameter: | 20" |
Propeller Pitch: | 20 |
Hoisting Engines |
Hoisting Engine Kind: | Double cylinder - steam |
Engine RPMs: | |
Engine Diameter: | 6" |
Engine Stroke: | 8" |
Engine Boiler: | Flue tube |
Engine Maker and Date: | Ledgerwood # 21414.5 |
Serial Number: | |
Cylinders and Size: | |
Horsepower: | |
Fuel: | |
Hoist Starter: | |
Hoist Miscellaneous: |
Miscellaneous |
General Information: | |
Boats on Station: | Boathouse & at mooring |